The
Electro-Acuscope 85 P is a pain management
system designed for functional precision
and reliability. Designed to fit the
needs of Sports Therapy ond Occupational
Medicine, it is the most advanced instrument
in its class.
To
Order Call,
Fax or Email Progressive Therapy Systems
We accept Checks,
Money Orders and All Major Credit/Debit
Cards
The EAS-85P
includes two independent modes.
Mode-1 is
a single output modality with two distinct functions.
The Display function provides complete control for
area assessment. This allows operator to check for
electrode contact and selection of treatment site.
The Gain Spectrum is provided to manipulate electrode
sensitivity and results are displayed on a 3 1/2
digit LCD meter. The audio signal follows the meter,
allowing for continuous electrode monitoring, without
having to refer back to the instrument.
The
Treatment mode has a three separate controls: frequency,
intensity and a timer. The treatment sequence is
triggered by a manual front panel trigger switch,
or by built-in electrode switch.
The
Mode-1 has a two sets of output jacks, used as one
set at a time. The main electrode output set is used
with all hand held control and point specific probes.
The remote electrode set is used with all placement
electrodes for unattended applications.
Mode-2 is
a dual channel modality. Each channel is independently
isolated and may be used simultaneously. The controls
are independent of each other therefore any variation
of intensity, frequency or time can be applied to
either output.
Each
channel is equipped with a 3 1/2 digit meter which
indicates the level of current passing in between
the electrodes. This mode can be used in many variations
of electrode applications. As an example, set of
placement electrodes is attached permanently, while
the operator is using area specific probe such
as double roller. In unattended application both
outputs can be used on the same patient, or two patient
treatment can be applied at the same time.
EAS-85P
SPECIFICATIONS
MODE
- 1 CONTROLS:
Power
- Off / On Control First Switch Position.
Timer
- 4, 6, 8, 12, 16, 30sec. 1, 3, 5, 10, 15 min & Cont.
Frequency
- 0.5, 1.0, 1.5, 2.0, 2.5, 8.0, 10, 20, 40, 80,
160, 320Hz.
Intensity
- 25, 50, 100, 200, 300, 500uA RMS.
Gain
Spectrum - Range: 000 Setting - 20K to 300K 999
Setting - 200K to 1Meg
Audio
Threshold - Volume.
Output
- Complex Wave Form, Modulated Square Wave Envelope
Frequency Modulated Pulse train with Alternating
of Current Polarity each 1 1/2 Seconds.
Two
Sets of Electrode Outputs. (Designed to be used
only one set at a time.)
Feedback
indicators - 3 1/2 Digit Meter Lo Batt Indicator
Loudspeaker Battery Voltage Monitor with Automatic
Power Cutoff at Preset Discharge Level.
MODE
2 - CONTROLS:
Both
Channels. Power - Off / On Control
Second Switch Position.
Timer
- 4, 6, 8, 12, 16, 30sec. 1, 3, 5, 10, 15 min & Cont.
Frequency
- 0.5, 1.0, 1.5, 2.0, 2.5, 8.0, 10, 20, 40, 80,
160, 320Hz.
Intensity
- 25, 50, 100, 200, 300, 500uA RMS.
Output
- Complex Wave Form, Modulated Square Wave Envelope
Frequency Modulated Pulse train with Alternating
of Current Polarity each 1 1/2 Seconds.
Isolated
Electrode Outputs.
Feedback
indicators - 3 1/2 Digit Current Flow Meter
SYSTEM:
- Power
Source - 24 Volt Rechargeable Lead-Acid
Battery
- Dimensions
- 20"
wide, 8" high, 16" deep
- Net
weight - 22 pounds
STANDARD
ACCESSORIES:
- Trigger
Probe, Indifferent Probe, Standard
Ball Tip Set, Y Probe, 1x1 Mini Plates,
Coil cords, Hand Bar, Spring Tip Probe,
Large Double Roller, Conductive Electrolyte,
Charger, Manual
Back
to Top
Major
credit cards accepted by phone, fax or
email.